Download I-view Communication Driver



  1. Download Iview Communication Drivers
  2. Download Iview Communication Driver Software
  3. Download Iview Communication Driver Windows 7

With over 25 years' experience in data acquisition from different sources, and hundreds of drivers to choose from, PcVue Solutions data acquisition layer (called also CIMWAY®) is the foundation of our real-time data infrastructure.
CIMWAY® offers a large range of scalable driver solutions for collecting data from automation devices. Communication is managed through a robust platform that supports a collection of standards drivers for Schneider Electric, Siemens, Rockwell, Mitsubishi, Wago,…. A driver development kit is also available for our customers to develop their own driver and obviously driver development is ongoing and new drivers are added continuously by our R&D team.

Download ASUS X543MA Atheros Bluetooth Driver 10.0.3.22 for Windows 10 64-bit (Bluetooth). It is highly recommended to always use the most recent driver version available. Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched. Hello acer technician, a person is asking drivers for 'pci simple communications controller'. Place that driver to your support site, without having to search for an obscure third-party sites.

Depending on the version of PcVue compatibilitiy and prerequisites may change. Please check documentations (release notes, readme) available on the KB.

INTERFACEDRIVER VERSION

S - Serial port
E - Ethernet port
Mb - Manufacturer board
N/S - Not Significant

Mo - Molex
O - OPC Server
H - Hilscher adapter
Native - Integrated in PcVue
Act - Activated on order
ManufacturerProtocol/EquipmentInterfaceRequirementVersion
ABBSPA-BUSSNative
ALSTOMESP GEM 80SNative
ALSTOMESP Gemlan-T TCP/IPENative
ALSTOMEthernet SRTPMoPCU2000ETH
ALSTOMEthernet SRTP for C80-75 & C80-35OSW1000ETH
ALSTOMEthernet SRTP for C80-75 & C80-35 Time stampedENative
ALSTOMNbus ASCII / RTUMoPCI1000/2000/4000 PCU1000
ALSTOMSNP-XMoPCI1000/2000/4000 PCU1000
ALSTOMSNP-X for C80-75 & C80-35OSW1000SER
ALSTOMTime stamped NbusOSW1000SER
BACnet - ASHRAEBACnet/IP client - BTL certified Profile B-AWSENative - Act
BACnet - ASHRAEBACnet/IP server - Profile B-ASCE
BECKHOFFTwinCat over TCP/IPETwinCat ADSNative
CERBERUSCERLOOPMoPCI1000/2000/4000 PCU1000
CITILOGIP-CitilogENative
COMMEND SACommend OPC ServerO
COMMEND SAICXENative - Act
CROUZETCBUSSNative
DNP USER GROUPDNP3 Master stationENative - Act
ECHELONLONMbLCA Object ServerNative
ECHELONLONENL220, LonMakerNative
EIBOPC EIBOEIBA Server
ELSAG BAILEYData LinkMoPCI1000/2000/4000 PCU1000
EMERSONDeltaV (DCS)ODeltaV OPC Server
FISHERROC protocol for Roc 300 Series, FloBoss 407 & 500 SeriesSNative
GE FANUCEthernet SRTPMoPCU2000ETH
GE FANUCEthernet SRTP for 90-70 & 90-30 Series Time stampedENative
GE FANUCSNP-XMoPCI1000/2000/4000 PCU1000
GE FANUCSNP-X for 90-70 & 90-30OSW1000SER or KEPServer
GenericSQL driverENative - Act
Generic GPS protocolStandard NMEA supported (GPPPA,GPGLL,GPGSA,GPGSV,GPRMC,GPVTG)SNative
HILSCHERMPI for Siemens S7-300 & S7-400 via EthernetHNetlink Adapter for MPINative - Act
HITACHIEX8000 - MLC 8000 systemENB : Ethernet TCP/IP Client & UDP ServerNative
HONEYWELLHC9000 EthernetOKEPServer
HONEYWELLPLANTSCAPE/EXPERION (DCS)OExperion OPC ServerNative
HONEYWELLUDC EthernetOKEPServer
HONEYWELLUDC SerialOKEPServer
IECIEC 60870-5-104 MasterENative - Act
IECIEC 60870-5-104 OutstationENative - Act
IECIEC 61850 Client - DNV-GL certifiedENative - Act
JOHNSON CONTROLSN2OPEN (Optomux)ONT9100 OPC Server
JOHNSON CONTROLSOptomux N2 for DX9100 & DC9100SDX & DC SeriesNative
JUMOJUMO_ASCIISNative
JUMOJUMO_JBUSSNative
KEPWAREAll supported protocolsOFor the complete list of supported protocols visit www.kepware.com
KERLINKLoRaENative - Act
KNXENative - Act
KROHNEBM100 BUSSNative
KROHNEBM100 PTPSNative
LANDIS&GYRNRU/NRKSNirmo gatewayNative
LEGRAND / BTICINOOpenSCSENative
LSISIP-XGTE
MATRIXPUPSNative
MATSUSHITAMewtocolSNative
MATSUSHITAMewtocol IPENative
MICROSOFTDDE clientN/SNative
MITSUBISHIFX 485SNative
MITSUBISHIFX-SeriesSNative
MITSUBISHIMelsec A-SeriesSNative
MITSUBISHIMelsec TCP/IP for A and Q SeriesENative
MTTME1000ERioTcplib.dll Librairy - Please contact MTT
MOELLERSucomAMoPCI1000/2000/4000 PCU1000
MOELLERSucomAOSW1000SER or KEPServer
MOLEXAll supported protocolsOFor the complete list of supported protocols visit www.molex.com (Network Interface Card)
MOXAMoxa ioLogik - Support controllers in the E1200 & E2500 seriesENative
MQTTMQTT - PublisherENative - Act
MQTTMQTT - SubscriberENative - Act
MULTITECHLoRaENative - Act
NAPAQXFLOW (RIO), TBCODevIO OPC Server
NATIONAL INSTRUMENTOptomux for FieldPoint and Compact FieldPointOOPC FIELD POINT SERVER
ODVACIPOSW1000ETH or KEPServer
OMRONAll OMRON protocolsOCX Server OPC or KEPServer
OMRONFINS TCPMoPCU2000ETH
OMRONFINS TCP for OMRON C, CV and CS seriesOSW1000ETH
OMRONSYSMAC-WAYSNative
OMRONSYSMAC-WAYMoPCI1000/2000/4000
OPC FoundationOPC-UA DA ServerN/SNative - Act
OPC FoundationOPC-UA DA ClientN/SNative - Act
OPC FoundationOPC-DA clientN/SNative
OPC FoundationOPC-DA ServerN/SNative
OPC FoundationOPC-XML DA clientN/SNative
OPTO22OptomuxSJohnson Controls DX 9100Native
PERAXP200,P400,P16ODevIO
PERAXPerax time stampedSARLEQUIN ConcentratorNative
PHOENIX CONTACTInterBus SOInterBus OPC Server
PROFIBUSAll messaging FMS / DP / FDL / S5 / S7 / MPIMoPCI1500PFB/2000PFB PCU1500PFB
PROFIBUSS7 / MPI onlyMoPCI1500S7 PCU1500S7 PCU1000PFB
QUADLOGAPACS M-BUSOAPACS OPC Server
ROCKWELL AUTOMATIONAll Allen Bradley protocolsORSLinx OEM or KEPServer
ROCKWELL AUTOMATIONDF1MoPCI1000/2000/4000 PCU1000
ROCKWELL AUTOMATIONDF1 / DH+ / EtherNet/IP etc.Mb/E/SRSLinx OEMNative
ROCKWELL AUTOMATIONDF1 peer to peer for SLC500 Serie onlySNative
ROCKWELL AUTOMATIONEtherNet/IP for PLC-5, SLC-500 and Logix 5000MoPCU2000ETH
ROCKWELL AUTOMATIONEtherNet/IP for Logix5000 access (CompactLogix, ControlLogix,DriveLogix and FlexLogix controllers)ENative - Act
SAIA BURGESS CONTROLSEther-S-NetENative
SAIA BURGESS CONTROLSS-NetSNative
SAUTERNovaNetSSauter OPC Server + ActiveX TimeTable
SCHNEIDER ELECTRICEthwayMoPCU2000ETH
SCHNEIDER ELECTRICModbus ASCII /RTU Slave Time stamped ModbusMoPCI1000/2000/4000 PCU1000
SCHNEIDER ELECTRICModbus ASCII /RTU Slave Time stamped ModbusOSW1000SER
SCHNEIDER ELECTRICModbus Master ASCII / RTU Time stamped ModbusSNative
SCHNEIDER ELECTRICModbus+MbNative
SCHNEIDER ELECTRICOpen Modbus TCP/IP Master Time stamped ModbusENative
SCHNEIDER ELECTRICOpen Modbus TCP/IP SlaveENative
SCHNEIDER ELECTRICEthwayOSchneider OFS OPC Server (time stamped not supported)
SCHNEIDER ELECTRICUni-TE TCP/IPMoPCU2000ETH
SCHNEIDER ELECTRICUni-TE TCP/IPOSW1000ETH
SCHNEIDER ELECTRICUni-TE TCP/IPOSchneider OFS OPC Server
SCHNEIDER ELECTRICUnitelway SlaveSClient SlaveNative
SCHNEIDER ELECTRICUnitelway SlaveMoPCI1000/2000/4000 PCU1000
SCHNEIDER ELECTRICUnitelway SlaveOSW1000SER
SCHNEIDER ELECTRICUnitelway SlaveOSchneider OFS OPC Server
SIEMENS3964 / 3964R, RK512 messaging via CP524 / 525SNative
SIEMENSAll messaging Profibus FMS / DP / FDL / MPI / PPI+ / PPIMoPCI1500PFB/2000PFB PCU1500PFB
SIEMENSAS511MoPCI1000/2000/4000 PCU1000
SIEMENSAS511 for S5 serie programming portOSW1000SER
SIEMENSIndustrial Ethernet ISO on TCP for S5 and TIMoPCU2000ETH
SIEMENSIndustrial Ethernet ISO on TCP for S5 and TIOSW1000ETH (H1 not supported)
SIEMENSIndustrial Ethernet ISO on TCP for S7ENative
SIEMENSIndustrial Ethernet TCP (Fetch / Write messaging) for S7-300 & 400ENative
SIEMENSS7 / MPIHNetlink (NL MPI, NT 40 MPI, NT50 MPI for ISO)Native - Act
SIEMENSS7 PPIESiemens USB/RS Multi-Master cable
SIEMENSSinec H1OSimatic Net or Matrikon
SIEMENSTI-DirectMoPCI1000/2000/4000 PCU1000
SIEMENSTI-Direct for TI505 serie programming portOSW1000SER
SIEMENS VideoIP Camera with: CCIS1337-LP/CFVA-IP/CVVA-IPOSIEMENS MK8000 OPC Server
SIEMENS VideoSIMATRIXOSIEMENS MK8000 OPC Server
SIEMENS VideoSISTORE AX/CX/MX (NVS included)/MXpro/SX recorder (DVRs)OSIEMENS MK8000 OPC Server
SIEMENS VideoTELSCAN (Video Web Server)OSIEMENS MK8000 OPC Server
SIEMENS Access controlCerPass CC30 Controller (SiPass connection)OSIEMENS MK8000 OPC Server
SIEMENS Access controlSiPassOSIEMENS MK8000 OPC Server
SIEMENS Fire DetectionCC60 GazOSIEMENS MK8000 OPC Server
SIEMENS Fire DetectionCS11 AlgoRexOSIEMENS MK8000 OPC Server
SIEMENS Fire DetectionCS1115OSIEMENS MK8000 OPC Server
SIEMENS Fire DetectionCZ10OSIEMENS MK8000 OPC Server
SIEMENS Fire DetectionFS20 Sinteso/FS720 Cerberus PROOSIEMENS MK8000 OPC Server
SIEMENS Fire DetectionSTT11 CMSIOSIEMENS MK8000 OPC Server
SIEMENS Fire DetectionSTT20 CMSIOSIEMENS MK8000 OPC Server
SIEMENS Fire DetectionSTT2410 CMSIOSIEMENS MK8000 OPC Server
SIEMENS Intrusion detectionCS4OSIEMENS MK8000 OPC Server
SIEMENS Intrusion detectionCS440OSIEMENS MK8000 OPC Server
SIEMENS Intrusion detectionCS6 Guarto (NK822x configuration and connection)OSIEMENS MK8000 OPC Server
SIEMENS Intrusion detectionCZ12OSIEMENS MK8000 OPC Server
SIEMENS Intrusion detectionSI410/420OSIEMENS MK8000 OPC Server
SNMPSNMP Manager V1, V2C and V3ENative - Act
SNMPSNMP AgentENative - Act
SOFRELS50, S500ODevIO OPC Server
SOFRELSofbus-PCSCS100 ConcentratorNative
SOFRELSofbus-PL, Lacbus-RTU, SMS for S500,LS,Box,S50OSoftrel OPC Server
TBOXSemaphore LT50, LP300, CLASSICODevIO OPC Server
TRENDIQ2, IQ3ODevIO OPC Server
TYCOIP POSMEPOSM XPro Video SystemNative
WAGOModbus ASCII / RTUPlease refer to the Schneider entry
WAGOOPEN COM (Open Modbus)Please refer to the Schneider entry
WAGOProfibus FMS / DP / FDLPlease refer to the Siemens or Profibus entry
WITTRS IIOPC Pilot
WITTRS II for WIT Force, Clip, Easy, TwinYODevIO OPC Server
YOKOGAWAEthernet TCP/IP for FA-M serieENative
YOKOGAWASerial protocol for FA-M serieSNative
YOKOGAWASTARDOM PLCODAC OPC Server

Details

Note:
Precautions for adding a new driver onto Windows Vista/7
TitleFuji Electric Co.,Ltd. MICREX-SX Series Ethernet Driver
VersionVer. 1.14.07
Applicable SoftwareGP-Pro EX Ver2.10.000 or later
Pro-Server EX Ver.1.30.000 or later
You can check your version by”Help”function→”Version Info”.
Related Devices
  • MICREX-SX Series
Related UnitsRequired versions depend on models.
Please check 'Supported Models / Version' for the required versions of GP-Pro EX.
Required driver versions for different models are listed below
ModelRequired driver version
GP3000 SeriesVer. 1.10.00 or later
LT3000 SeriesVer. 1.12.05 or later
GP4100 SeriesGP4104Ver. 1.11.04 or later
GP4114Ver. 1.14.06 or later
GP4000M SeriesVer. 1.11.04 or later
GP4000 SeriesVer. 1.11.05 or later
LT4000M SeriesVer. 1.12.05 or later
SP5000 SeriesVer. 1.13.06 or later
SP5000X SeriesVer. 1.14.06 or later
IPC Series for WinGPVer. 1.10.00 or later
General PCs for WinGPVer. 1.10.00 or later
Device/PLC Connection ManualFor general information regarding Device connection and documentation conventions please refer to 'Device/PLC Connection Manual(link is external)'
Updated Contents

[Ver. 1.14.07] (Aug, 31, 2020)

The following issues were corrected:
  • When running an error check on a project, sometimes the outer limits of address ranges could not be detected properly.
Download iview communication driver updaterDownload I-view Communication Driver

Download Iview Communication Drivers

How to install (This is a self-extracting file.)

Please confirm that the supported software is installed in your computer. Prior to installing the driver, close all your personal computer applications, including any resident programs such as virus detection program, etc.
  1. Click on the above file name to download the data to desired folder.
  2. After the download to your PC is finished, double-click on the file’s icon to start the installer program.
  3. After the installer starts, follow the instructions given on each screen.
  4. After installation, execute GP-Pro EX.
  5. Click on the Device/PLC area’s [Fuji Electric Co.,Ltd.] selection and select [MICREX-SX Series Ethernet].
When using the driver, be sure to refer to the Device Connection Manual PDF.
Also, for general information regarding Device connection and documentation conventions please refer to 'Device/PLC Connection Manual'.

In case of using a project, created with a version below than V1.10.03

Download Iview Communication Driver Software

It is necessary to reallocate a variable to a real address when using variable data.
Instructions on how to reallocate to real address.
  1. Open the project file with driver V1.10.03 or later, installed in GP-Pro EX.
  2. Open the “Variable List” dialog from the Individual Device Settings.
  3. Delete all of the worksheet(s) (This will delete all Variable Data)
  4. Delete all Structure / Array (If there are Embedded Structures / 2D Arrays then the higher level must be deleted first.)
  5. Import / Re-enter Structures / Arrays
  6. Import / Re-enter Variables
  7. Click OK to close dialog
  8. Click OK to save new Variable Data
* Please don’t close the “Variable List” dialog while doing the procedures above. If the “Variable List” dialog is closed, the allocated variables to the parts in the screen will become “-Undefined-“.

Terms of use / Cautions

Please acknowledge the following terms of use before you use our download service.
Download of any file signifies your agreement to the terms of use.
Terms and conditions

Download file

Installer :
1.02 MB (1,069,304Byte)
Device/PLC Connection Manual :
818.51 KB (838,152Byte)

Update history:


[Ver. 1.14.07] (Aug. 31, 2020)

The following issues were corrected:
  • When running an error check on a project, sometimes the outer limits of address ranges could not be detected properly.
Download I-view Communication Driver


[Ver. 1.13.06]

Communication

Download Iview Communication Driver Windows 7

The following issues were corrected:
  • Variable data cannot be imported normally when D300win V3.6.1.3 or later is used.
Download I-view Communication Driver


[Ver. 1.10.03] (Dec. 24, 2010)

The following issues were corrected:
  • In rare cases, a variable that have been allocated to a real address, is unmatched with the Fuji Electric Co. Ltd. Micrex-SX Series D300Win software.
  • In rare cases, the displayed address in the left side of the [Address] window is unfinished.
  • In rare cases, putting a comment or space in the IEC file will result in an error when importing.


[Ver. 1.10.02] (Nov. 12, 2009)

The following issues were corrected:
  • GP-Pro EX may be forcibly terminated when the address input dialog is opened.
  • GP-Pro EX may stop responding when import is performed and variables are overwritten.


[Ver. 1.10.01](May. 8, 2008)

The following issues were corrected:
  • When create structure in variable data, there is the case that display cannot communicate with PLC.